Selective Separation, Preconcentration, and Determination of Au (III) Ions in Environmental Samples by Coprecipitation With a 1,2,4-Triazole Derivative

MakaleYalnız künyeScopus SJRQ3

Özet

An effective, simple, lowcost, and accurate separation and preconcentration procedure which has minimal impact on the environment has been developed. It is based on the carrier element-free coprecipitation (CEFC) of Au(III)ions using N-benzyl-2-{[3-methyl-4-(2morpholine-4-ylethyl)-5-oxo-4,5-dihydro-1H-1,2, 4-triazole-1-yl] acetyl)hydrazinecarboxamide (BODAH) as an organic coprecipitant. Determination of the Au(IH) ion levels was performed by flame atomic absorption spectrometry (FAAS). The developed method provided a detection limit of 0.36 μg L-1 and the relative standard deviation for Au(III)ions was found to be 5.1%. Spike tests and certified reference material analyses were performed to validate the method. The developed method was systematically investigated in different sets of experimental parameters that influence the quantitative recovery of the Au(III)ions. Based on these investigations, the optimum conditions for the determination of Au(III) ions at trace levels were established. The coprecipitation method was applied to anodic slime, gold ore, soil, and water samples to determine their Au(III)levels.

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/12417Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
6
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorOzdes, Duygu
dc.contributor.authorDuran, Celal
dc.contributor.authorSerencam, Huseyin
dc.contributor.authorŞahin, Deniz
dc.date.accessioned2026-10-29T19:09:33.555138300Z
dc.date.available2026-10-29T19:09:33.555138300Z
dc.date.issued2013
dc.description.abstractAn effective, simple, lowcost, and accurate separation and preconcentration procedure which has minimal impact on the environment has been developed. It is based on the carrier element-free coprecipitation (CEFC) of Au(III)ions using N-benzyl-2-{[3-methyl-4-(2morpholine-4-ylethyl)-5-oxo-4,5-dihydro-1H-1,2, 4-triazole-1-yl] acetyl)hydrazinecarboxamide (BODAH) as an organic coprecipitant. Determination of the Au(IH) ion levels was performed by flame atomic absorption spectrometry (FAAS). The developed method provided a detection limit of 0.36 μg L-1 and the relative standard deviation for Au(III)ions was found to be 5.1%. Spike tests and certified reference material analyses were performed to validate the method. The developed method was systematically investigated in different sets of experimental parameters that influence the quantitative recovery of the Au(III)ions. Based on these investigations, the optimum conditions for the determination of Au(III) ions at trace levels were established. The coprecipitation method was applied to anodic slime, gold ore, soil, and water samples to determine their Au(III)levels.
dc.identifier.endpage169
dc.identifier.issn0195-5373
dc.identifier.issue5
dc.identifier.scopus2-s2.0-84890265125
dc.identifier.startpage164
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/12417
dc.identifier.volume34
dc.language.isoen
dc.relation.ispartofAtomic Spectroscopy
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.titleSelective Separation, Preconcentration, and Determination of Au (III) Ions in Environmental Samples by Coprecipitation With a 1,2,4-Triazole Derivative
dc.typeArticle
rdl.citation.scopus6
rdl.oa.statusclosed
rdl.scopus.quartileQ3
rdl.source.indexSCOPUS