Experimental research of dynamic instabilities in the presence of coiled wire inserts on two-phase flow

MakaleAçık ErişimScopus SJRQ2

Özet

The aim of this study is to experimentally investigate the effect of the coiled wire insertions on dynamic instabilities and to compare the results with the smooth tube for forced convection boiling. The experiments were conducted in a circular tube, and water was used as the working fluid. Two different pitch ratios (H / D = 2.77 and 5.55) of coiled wire with circular cross-sections were utilised. The constant heat flux boundary condition was applied to the outer side of the test tube, and the constant exit restriction was used at the tube outlet. The mass flow rate changed from 110 to 20 g/s in order to obtain a detailed idea about the density wave and pressure drop oscillations, and the range of the inlet temperature was 15-35°C. The changes in pressure drop, inlet temperature, amplitude, and the period with mass flow rate are presented. For each configuration, it is seen that density wave and pressure drop oscillations occur at all inlet temperatures. Analyses show that the decrease in the mass flow rate and inlet temperature causes the amplitude and the period of the density wave and the pressure drop oscillations to decrease separately.

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/12251Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1155/2013/714180Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
2
WoS
1
OpenAlex
4
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorOmeroglu, Gokhan
dc.contributor.authorComakli, Omer
dc.contributor.authorKaragoz, Sendogan
dc.contributor.authorSahin, Bayram
dc.date.accessioned2026-10-29T19:09:22.126870008Z
dc.date.available2026-10-29T19:09:22.126870008Z
dc.date.issued2013
dc.description.abstractThe aim of this study is to experimentally investigate the effect of the coiled wire insertions on dynamic instabilities and to compare the results with the smooth tube for forced convection boiling. The experiments were conducted in a circular tube, and water was used as the working fluid. Two different pitch ratios (H / D = 2.77 and 5.55) of coiled wire with circular cross-sections were utilised. The constant heat flux boundary condition was applied to the outer side of the test tube, and the constant exit restriction was used at the tube outlet. The mass flow rate changed from 110 to 20 g/s in order to obtain a detailed idea about the density wave and pressure drop oscillations, and the range of the inlet temperature was 15-35°C. The changes in pressure drop, inlet temperature, amplitude, and the period with mass flow rate are presented. For each configuration, it is seen that density wave and pressure drop oscillations occur at all inlet temperatures. Analyses show that the decrease in the mass flow rate and inlet temperature causes the amplitude and the period of the density wave and the pressure drop oscillations to decrease separately.
dc.description.sponsorshipBAP of the Research Fund of Ataturk University
dc.identifier.articlenumber714180
dc.identifier.doi10.1155/2013/714180
dc.identifier.issn1537-744X
dc.identifier.pmcidPMC3556885
dc.identifier.pmid23365547
dc.identifier.scopus2-s2.0-84873400345
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/12251
dc.identifier.volume2013
dc.identifier.wosWOS:000313735800001
dc.language.isoen
dc.publisherHINDAWI LTD
dc.relation.ispartofThe Scientific World Journal
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subject.classificationMultidisciplinary Sciences
dc.subject.classificationScience & Technology - Other Topics
dc.subject.otherComputer Simulation
dc.subject.otherEquipment Design
dc.subject.otherEquipment Failure Analysis
dc.subject.otherHeating
dc.subject.otherModels, Theoretical
dc.subject.otherNonlinear Dynamics
dc.subject.otherRheology
dc.subject.otherwater
dc.subject.otherMLCS
dc.subject.otherMLOWN
dc.subject.otherarticle
dc.subject.otherdensity
dc.subject.otherflow rate
dc.subject.otherheat transfer
dc.subject.othermass
dc.subject.otheroscillation
dc.subject.otherpitch
dc.subject.otherpressure
dc.subject.othersteady state
dc.subject.othertemperature
dc.subject.otherequipment
dc.subject.otherequipment failure
dc.subject.otherflow kinetics
dc.subject.othermethodology
dc.subject.othernonlinear system
dc.subject.othertheoretical model
dc.titleExperimental research of dynamic instabilities in the presence of coiled wire inserts on two-phase flow
dc.typeArticle
rdl.citation.openalex4
rdl.citation.scopus2
rdl.citation.wos1
rdl.departmentDepartment of Mechanical Engineering, Faculty of Engineering, Bayburt University, Bayburt, Turkey
rdl.oa.statusgold
rdl.oa.statusgreen
rdl.oa.urlhttps://downloads.hindawi.com/journals/tswj/2013/714180.pdf
rdl.scopus.quartileQ2
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.source.indexPUBMED
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)