Performance Analysis of Buck-Boost and SEPIC Converter for Commutation Torque Ripple Minimization in BLDC Motors

MakaleAçık ErişimScopus SJRQ3
  • SDG 7 · Erişilebilir ve Temiz Enerji

Özet

This paper discusses comparative analysis of Buck-Boost and SEPIC (Single Ended Primary Inductance) converters used in DC link voltage control technique to reduce torque ripple in Brushless Direct Current Motors (BLDCM). The aim of this study is to prove the efficiency of the aforementioned two converters, which have been adopted in many studies to reduce torque ripples caused by commutation, on the same motor parameters. Although BLDCM has many advantages, ripples in the generated torque have limited the use of these motors in applications requiring precise speed and torque. In this study, BLDCM was analyzed exhaustive mathematically and electrically and the problem that caused commutation torque ripples was explained in detail. The DC link voltage control has been proposed to suppressing torque ripples in the BLDCM. In addition, the link voltages required for reducing the torque ripples were obtained separately via both the Buck-Boost and the SEPIC converters. These converter topologies are examined under certain speed and torque conditions and the results were compared. When the results are evaluated together, it was observed that both converters performed the very closely performance each other. However, the Buck-Boost converter produced the desired voltage levels with less oscillation than the SEPIC converter.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/12103Resmi atıflarda kullanılan kalıcı adres
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
5
WoS
2
OpenAlex
3
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorÇorapsız, Muhammed Reşit
dc.contributor.authorKahveci, Hakan
dc.date.accessioned2026-10-29T19:09:11.520572017Z
dc.date.available2026-10-29T19:09:11.520572017Z
dc.date.issued2022
dc.description.abstractThis paper discusses comparative analysis of Buck-Boost and SEPIC (Single Ended Primary Inductance) converters used in DC link voltage control technique to reduce torque ripple in Brushless Direct Current Motors (BLDCM). The aim of this study is to prove the efficiency of the aforementioned two converters, which have been adopted in many studies to reduce torque ripples caused by commutation, on the same motor parameters. Although BLDCM has many advantages, ripples in the generated torque have limited the use of these motors in applications requiring precise speed and torque. In this study, BLDCM was analyzed exhaustive mathematically and electrically and the problem that caused commutation torque ripples was explained in detail. The DC link voltage control has been proposed to suppressing torque ripples in the BLDCM. In addition, the link voltages required for reducing the torque ripples were obtained separately via both the Buck-Boost and the SEPIC converters. These converter topologies are examined under certain speed and torque conditions and the results were compared. When the results are evaluated together, it was observed that both converters performed the very closely performance each other. However, the Buck-Boost converter produced the desired voltage levels with less oscillation than the SEPIC converter.
dc.identifier.doi10.1080/15325008.2022.2049653
dc.identifier.eissn1532-5016
dc.identifier.endpage1067
dc.identifier.issn1532-5008
dc.identifier.issue11-12
dc.identifier.scopus2-s2.0-85128644892
dc.identifier.startpage1052
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/12103
dc.identifier.volume49
dc.identifier.wosWOS:000779259900001
dc.language.isoen
dc.publisherTaylor and Francis Ltd.
dc.relation.ispartofElectric Power Components and Systems
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectbrushless DC motor
dc.subjectbuck-boost converter
dc.subjectcommutation torque ripples
dc.subjectDC-link voltage control
dc.subjectsepic converter
dc.subject.classificationEngineering, Electrical & Electronic
dc.subject.classificationEngineering
dc.subject.otherAC motors
dc.subject.otherDC-DC converters
dc.subject.otherElectric current regulators
dc.subject.otherElectric machine control
dc.subject.otherTorque
dc.subject.otherVoltage control
dc.subject.otherBrushless DC-motors
dc.subject.otherBrushless direct current motor
dc.subject.otherBuck-boost
dc.subject.otherBuck/boost converters
dc.subject.otherCommutation torque ripple
dc.subject.otherDC link voltage control
dc.subject.otherPerformances analysis
dc.subject.otherSEPIC converter
dc.subject.otherSingle-ended
dc.subject.otherTorque ripples
dc.subject.otherBrushless DC motors
dc.titlePerformance Analysis of Buck-Boost and SEPIC Converter for Commutation Torque Ripple Minimization in BLDC Motors
dc.typeArticle
rdl.citation.openalex3
rdl.citation.scopus5
rdl.citation.wos2
rdl.oa.statusclosed
rdl.oa.statusgreen
rdl.oa.urlhttp://hdl.handle.net/20.500.12403/3583
rdl.scopus.quartileQ3
rdl.sdgSDG07
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)