Thermodynamic feasibility analysis of a newly modified absorption power cycle running with LiBr-water

MakaleYalnız künyeScopus SJRQ2
  • SDG 7 · Erişilebilir ve Temiz Enerji
  • SDG 9 · Sanayi, Yenilikçilik ve Altyapı
  • SDG 13 · İklim Eylemi

Özet

This study thermodynamically evaluates a newly modified absorption power cycle (APC) working with Lithium Bromide–Water (LiBr-H2O) solution and compares it with the conventional Rankine, one-stage, and three-stage APC systems. An additional steam condenser is integrated to the conventional APC and part of pure water is extracted and pumped back to the high-pressure side without passing through the absorber of the cycle. In order to specify the best system parameters, parametric optimization of all configurations is evaluated. The Rankine cycle and the modified APC have better thermodynamic performances than those of the conventional and the three-stage APC at generator temperatures. The conventional APC is found to improve the cycle performance at low generator pressure. However, the efficiencies of this cycle start to decrease when generator pressure increases. In contrast, the Rankine cycle and the modified APC have larger working ranges of generator pressure.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/12073Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1002/ep.13483Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
8
WoS
5
OpenAlex
7
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorTozlu, Alperen
dc.contributor.authorYosaf, Salem A.
dc.contributor.authorÖzcan, Hasan
dc.date.accessioned2026-10-29T19:09:09.497110867Z
dc.date.available2026-10-29T19:09:09.497110867Z
dc.date.issued2021
dc.description.abstractThis study thermodynamically evaluates a newly modified absorption power cycle (APC) working with Lithium Bromide–Water (LiBr-H2O) solution and compares it with the conventional Rankine, one-stage, and three-stage APC systems. An additional steam condenser is integrated to the conventional APC and part of pure water is extracted and pumped back to the high-pressure side without passing through the absorber of the cycle. In order to specify the best system parameters, parametric optimization of all configurations is evaluated. The Rankine cycle and the modified APC have better thermodynamic performances than those of the conventional and the three-stage APC at generator temperatures. The conventional APC is found to improve the cycle performance at low generator pressure. However, the efficiencies of this cycle start to decrease when generator pressure increases. In contrast, the Rankine cycle and the modified APC have larger working ranges of generator pressure.
dc.identifier.articlenumbere13483
dc.identifier.doi10.1002/ep.13483
dc.identifier.eissn1944-7450
dc.identifier.issn1944-7442
dc.identifier.issue1
dc.identifier.scopus2-s2.0-85089135047
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/12073
dc.identifier.volume40
dc.identifier.wosWOS:000557385100001
dc.language.isoen
dc.publisherJohn Wiley and Sons Inc
dc.relation.ispartofEnvironmental Progress and Sustainable Energy
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectabsorption power cycle
dc.subjectenergy
dc.subjectexergy
dc.subjectLiBr-water
dc.subjectRankine cycle
dc.subject.classificationGreen & Sustainable Science & Technology
dc.subject.classificationEngineering, Environmental
dc.subject.classificationEngineering, Chemical
dc.subject.classificationEnvironmental Sciences
dc.subject.classificationScience & Technology - Other Topics
dc.subject.classificationEngineering
dc.subject.classificationEnvironmental Sciences & Ecology
dc.subject.otherBromine compounds
dc.subject.otherLithium bromide
dc.subject.otherRankine cycle
dc.subject.otherSteam condensers
dc.subject.otherAbsorption power cycle
dc.subject.otherCycle performance
dc.subject.otherGenerator temperature
dc.subject.otherHigh pressure
dc.subject.otherParametric optimization
dc.subject.otherPressure increase
dc.subject.otherThermodynamic feasibility
dc.subject.otherThermodynamic performance
dc.subject.otherWater absorption
dc.titleThermodynamic feasibility analysis of a newly modified absorption power cycle running with LiBr-water
dc.typeArticle
rdl.citation.openalex7
rdl.citation.scopus8
rdl.citation.wos5
rdl.oa.statusclosed
rdl.scopus.quartileQ2
rdl.sdgSDG07
rdl.sdgSDG13
rdl.sdgSDG09
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)