Simpler Reference-Plane-Invariant Method for Permittivity Extraction of Medium- or Low-Loss Dielectric Samples Using One-Port Measurements
Özet
A microwave method is devised to extract relative complex permittivity (ϵr) of medium- or low-loss dielectric samples. It is simpler, non-iterative, reference-plane-invariant (RPI), and applicable for one-port waveguide measurements with short-circuit termination only. Besides, since it uses short-circuit termination reflection-only measurements, it is free from Fabry-Pérot resonances. Permittivity measurements of polyvinyl chloride (PVC) and polypropylene (PP) are performed at X-band (8.2-12.4 GHz) to examine the performance of the proposed method considering different scenarios involving inaccurate information of sample location in the cell and inaccurate knowledge of the sample thickness. Repeatability analysis is carried out to analyze the performance of the proposed method against other similar methods in the literature.
Anahtar Kelimeler
- Scopus
- 6
- WoS
- 5
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Cem Hasar, Ugur | |
| dc.contributor.author | Ali, Husain | |
| dc.contributor.author | Kaya, Yunus | |
| dc.contributor.author | Stoyanov, Ivaylo | |
| dc.date.accessioned | 2026-10-29T19:08:49.860151562Z | |
| dc.date.available | 2026-10-29T19:08:49.860151562Z | |
| dc.date.issued | 2024 | |
| dc.description.abstract | A microwave method is devised to extract relative complex permittivity (ϵr) of medium- or low-loss dielectric samples. It is simpler, non-iterative, reference-plane-invariant (RPI), and applicable for one-port waveguide measurements with short-circuit termination only. Besides, since it uses short-circuit termination reflection-only measurements, it is free from Fabry-Pérot resonances. Permittivity measurements of polyvinyl chloride (PVC) and polypropylene (PP) are performed at X-band (8.2-12.4 GHz) to examine the performance of the proposed method considering different scenarios involving inaccurate information of sample location in the cell and inaccurate knowledge of the sample thickness. Repeatability analysis is carried out to analyze the performance of the proposed method against other similar methods in the literature. | |
| dc.description.sponsorship | European Union-NextGeneration EU | |
| dc.description.sponsorship | National Recovery and Resilience Plan of the Republic of Bulgaria, (BG-RRP-2.013-0001-C01) | |
| dc.identifier.doi | 10.1109/access.2024.3479311 | |
| dc.identifier.endpage | 151074 | |
| dc.identifier.issn | 2169-3536 | |
| dc.identifier.scopus | 2-s2.0-85207708999 | |
| dc.identifier.startpage | 151063 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/bayburt/11810 | |
| dc.identifier.volume | 12 | |
| dc.identifier.wos | WOS:001340691800001 | |
| dc.language.iso | en | |
| dc.publisher | Institute of Electrical and Electronics Engineers Inc. | |
| dc.relation.ispartof | IEEE Access | |
| dc.rights | info:eu-repo/semantics/openAccess | |
| dc.subject | Material characterization | |
| dc.subject | non-iterative | |
| dc.subject | one-port measurement | |
| dc.subject | permittivity | |
| dc.subject | short-termination | |
| dc.subject.classification | Computer Science, Information Systems | |
| dc.subject.classification | Engineering, Electrical & Electronic | |
| dc.subject.classification | Telecommunications | |
| dc.subject.classification | Computer Science | |
| dc.subject.classification | Engineering | |
| dc.subject.other | Circuit resonance | |
| dc.subject.other | Fabry-Perot interferometers | |
| dc.subject.other | Masers | |
| dc.subject.other | Strain measurement | |
| dc.subject.other | Thickness measurement | |
| dc.subject.other | Invariant methods | |
| dc.subject.other | Low-loss | |
| dc.subject.other | Materials characterization | |
| dc.subject.other | Non-iterative | |
| dc.subject.other | One-port measurement | |
| dc.subject.other | Performance | |
| dc.subject.other | Port measurements | |
| dc.subject.other | Reference plane | |
| dc.subject.other | Short terminations | |
| dc.subject.other | Simple++ | |
| dc.subject.other | Permittivity measurement | |
| dc.title | Simpler Reference-Plane-Invariant Method for Permittivity Extraction of Medium- or Low-Loss Dielectric Samples Using One-Port Measurements | |
| dc.type | Article | |
| rdl.citation.scopus | 6 | |
| rdl.citation.wos | 5 | |
| rdl.oa.status | gold | |
| rdl.oa.url | https://doi.org/10.1109/access.2024.3479311 | |
| rdl.scopus.quartile | Q1 | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |