Simpler Reference-Plane-Invariant Method for Permittivity Extraction of Medium- or Low-Loss Dielectric Samples Using One-Port Measurements

MakaleAçık ErişimScopus SJRQ1

Özet

A microwave method is devised to extract relative complex permittivity (ϵr) of medium- or low-loss dielectric samples. It is simpler, non-iterative, reference-plane-invariant (RPI), and applicable for one-port waveguide measurements with short-circuit termination only. Besides, since it uses short-circuit termination reflection-only measurements, it is free from Fabry-Pérot resonances. Permittivity measurements of polyvinyl chloride (PVC) and polypropylene (PP) are performed at X-band (8.2-12.4 GHz) to examine the performance of the proposed method considering different scenarios involving inaccurate information of sample location in the cell and inaccurate knowledge of the sample thickness. Repeatability analysis is carried out to analyze the performance of the proposed method against other similar methods in the literature.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/11810Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1109/access.2024.3479311Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
6
WoS
5
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorCem Hasar, Ugur
dc.contributor.authorAli, Husain
dc.contributor.authorKaya, Yunus
dc.contributor.authorStoyanov, Ivaylo
dc.date.accessioned2026-10-29T19:08:49.860151562Z
dc.date.available2026-10-29T19:08:49.860151562Z
dc.date.issued2024
dc.description.abstractA microwave method is devised to extract relative complex permittivity (ϵr) of medium- or low-loss dielectric samples. It is simpler, non-iterative, reference-plane-invariant (RPI), and applicable for one-port waveguide measurements with short-circuit termination only. Besides, since it uses short-circuit termination reflection-only measurements, it is free from Fabry-Pérot resonances. Permittivity measurements of polyvinyl chloride (PVC) and polypropylene (PP) are performed at X-band (8.2-12.4 GHz) to examine the performance of the proposed method considering different scenarios involving inaccurate information of sample location in the cell and inaccurate knowledge of the sample thickness. Repeatability analysis is carried out to analyze the performance of the proposed method against other similar methods in the literature.
dc.description.sponsorshipEuropean Union-NextGeneration EU
dc.description.sponsorshipNational Recovery and Resilience Plan of the Republic of Bulgaria, (BG-RRP-2.013-0001-C01)
dc.identifier.doi10.1109/access.2024.3479311
dc.identifier.endpage151074
dc.identifier.issn2169-3536
dc.identifier.scopus2-s2.0-85207708999
dc.identifier.startpage151063
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/11810
dc.identifier.volume12
dc.identifier.wosWOS:001340691800001
dc.language.isoen
dc.publisherInstitute of Electrical and Electronics Engineers Inc.
dc.relation.ispartofIEEE Access
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectMaterial characterization
dc.subjectnon-iterative
dc.subjectone-port measurement
dc.subjectpermittivity
dc.subjectshort-termination
dc.subject.classificationComputer Science, Information Systems
dc.subject.classificationEngineering, Electrical & Electronic
dc.subject.classificationTelecommunications
dc.subject.classificationComputer Science
dc.subject.classificationEngineering
dc.subject.otherCircuit resonance
dc.subject.otherFabry-Perot interferometers
dc.subject.otherMasers
dc.subject.otherStrain measurement
dc.subject.otherThickness measurement
dc.subject.otherInvariant methods
dc.subject.otherLow-loss
dc.subject.otherMaterials characterization
dc.subject.otherNon-iterative
dc.subject.otherOne-port measurement
dc.subject.otherPerformance
dc.subject.otherPort measurements
dc.subject.otherReference plane
dc.subject.otherShort terminations
dc.subject.otherSimple++
dc.subject.otherPermittivity measurement
dc.titleSimpler Reference-Plane-Invariant Method for Permittivity Extraction of Medium- or Low-Loss Dielectric Samples Using One-Port Measurements
dc.typeArticle
rdl.citation.scopus6
rdl.citation.wos5
rdl.oa.statusgold
rdl.oa.urlhttps://doi.org/10.1109/access.2024.3479311
rdl.scopus.quartileQ1
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)