Improved Method for Permittivity Determination of Dielectric Samples by Free-Space Measurements

MakaleAçık ErişimScopus SJRQ1

Özet

A new deembedding technique is proposed for relative complex permittivity epsilon(r) determination of dielectric materials using gated free-space measurements. Its three main features are 1) it does not require any formal calibration procedure (calibration-free); 2) it is position-insensitive; and 3) it extracts ripple-free epsilon(r) due to gating process. The objective function derived to determine epsilon(r) by the proposed method is validated by free-space measurements of three dielectric samples (polypropylene, polyethylene, and polyoxymethylene). Besides, the accuracy of our method is compared with the accuracy of other calibrationfree and calibration-dependent methods in the literature.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/10799Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1109/tim.2022.3153991Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
49
WoS
36
OpenAlex
44
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorHasar, Ugur Cem
dc.contributor.authorKaya, Yunus
dc.contributor.authorOzturk, Hamdullah
dc.contributor.authorIzginli, Mucahit
dc.contributor.authorErtugrul, Mehmet
dc.contributor.authorBarroso, Joaquim Jose
dc.contributor.authorRamahi, Omar M.
dc.date.accessioned2026-10-29T17:19:30.507639155Z
dc.date.available2026-10-29T17:19:30.507639155Z
dc.date.issued2022
dc.description.abstractA new deembedding technique is proposed for relative complex permittivity epsilon(r) determination of dielectric materials using gated free-space measurements. Its three main features are 1) it does not require any formal calibration procedure (calibration-free); 2) it is position-insensitive; and 3) it extracts ripple-free epsilon(r) due to gating process. The objective function derived to determine epsilon(r) by the proposed method is validated by free-space measurements of three dielectric samples (polypropylene, polyethylene, and polyoxymethylene). Besides, the accuracy of our method is compared with the accuracy of other calibrationfree and calibration-dependent methods in the literature.
dc.description.sponsorshipUK Research and Innovation, UKRI, (27310)
dc.description.sponsorshipUK Research and Innovation, UKRI
dc.identifier.articlenumber6002108
dc.identifier.doi10.1109/tim.2022.3153991
dc.identifier.eissn1557-9662
dc.identifier.issn0018-9456
dc.identifier.scopus2-s2.0-85125330581
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/10799
dc.identifier.volume71
dc.identifier.wosWOS:000770592900011
dc.language.isoen
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
dc.relation.ispartofIEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectComplex permittivity
dc.subjectdeembedding technique
dc.subjectfree-space
dc.subjectgating
dc.subjectuncalibrated measurements
dc.subject.classificationEngineering, Electrical & Electronic
dc.subject.classificationInstruments & Instrumentation
dc.subject.classificationEngineering
dc.subject.otherCALIBRATION-INDEPENDENT METHOD
dc.subject.otherCOMPLEX PERMITTIVITY
dc.subject.otherREFLECTION
dc.subject.otherRETRIEVAL
dc.subject.otherCONSTANT
dc.subject.otherRECONSTRUCTION
dc.subject.otherPARAMETERS
dc.subject.otherTHICKNESS
dc.titleImproved Method for Permittivity Determination of Dielectric Samples by Free-Space Measurements
dc.typeArticle
rdl.citation.openalex44
rdl.citation.scopus49
rdl.citation.wos36
rdl.oa.statuspreprint
rdl.oa.statusgreen
rdl.oa.urlhttp://openaccess.hku.edu.tr/xmlui/bitstream/20.500.11782/2640/1/WOS000770592900011.pdf
rdl.scopus.quartileQ1
rdl.source.indexWOS
rdl.source.indexSCOPUS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)