Monitoring macro voids in mortars by computerized tomography method
Özet
This study aims to investigate the use of ground pumice powder (PP) in cement production and to monitor void developments in mortars by X-ray Computerized Tomography (CT) which is a nondestructive test method. PP-blended cements were produced by replacing ordinary Portland cement with PP at 0% (control), 5%, 10% and 15% by weight. Paste and mortar specimens were manufactured by these blended cements. Some of the physical and mechanical tests are carried out on these mortar specimens. Experimental results showed that macro void developments in 100-day period for mortars with different PP replacement ratios exhibited different reduction in void ratios.
Anahtar Kelimeler
RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/13887Resmi atıflarda kullanılan kalıcı adresİndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.Atıflar
- Scopus
- 19
- WoS
- 17
- OpenAlex
- 19
Tam Kayıt
| Alan | Değer | Dil |
|---|---|---|
| dc.contributor.author | Tekin, Ilker | |
| dc.contributor.author | Birgul, Recep | |
| dc.contributor.author | Ozgur Yaman, Ismail | |
| dc.contributor.author | Gencel, Osman | |
| dc.contributor.author | Yilmaz Aruntas, Huseyin | |
| dc.date.accessioned | 2026-10-29T19:11:35.683222728Z | |
| dc.date.available | 2026-10-29T19:11:35.683222728Z | |
| dc.date.issued | 2015 | |
| dc.description.abstract | This study aims to investigate the use of ground pumice powder (PP) in cement production and to monitor void developments in mortars by X-ray Computerized Tomography (CT) which is a nondestructive test method. PP-blended cements were produced by replacing ordinary Portland cement with PP at 0% (control), 5%, 10% and 15% by weight. Paste and mortar specimens were manufactured by these blended cements. Some of the physical and mechanical tests are carried out on these mortar specimens. Experimental results showed that macro void developments in 100-day period for mortars with different PP replacement ratios exhibited different reduction in void ratios. | |
| dc.identifier.doi | 10.1016/j.measurement.2014.11.034 | |
| dc.identifier.eissn | 1873-412X | |
| dc.identifier.endpage | 308 | |
| dc.identifier.issn | 0263-2241 | |
| dc.identifier.scopus | 2-s2.0-84920722898 | |
| dc.identifier.startpage | 299 | |
| dc.identifier.uri | https://rdlopen.rawdatalibrary.net/r/bayburt/13887 | |
| dc.identifier.volume | 63 | |
| dc.identifier.wos | WOS:000348030500033 | |
| dc.language.iso | en | |
| dc.publisher | Elsevier B.V. | |
| dc.relation.ispartof | Measurement: Journal of the International Measurement Confederation | |
| dc.rights | info:eu-repo/semantics/closedAccess | |
| dc.subject | Cement mortar | |
| dc.subject | Computerized tomography | |
| dc.subject | Nondestructive testing | |
| dc.subject | Porosity | |
| dc.subject | Strength | |
| dc.subject | Void distribution | |
| dc.subject.classification | Engineering, Multidisciplinary | |
| dc.subject.classification | Instruments & Instrumentation | |
| dc.subject.classification | Engineering | |
| dc.subject.other | Cements | |
| dc.subject.other | Mortar | |
| dc.subject.other | Nondestructive examination | |
| dc.subject.other | Porosity | |
| dc.subject.other | Portland cement | |
| dc.subject.other | Strength of materials | |
| dc.subject.other | Cement mortars | |
| dc.subject.other | Cement production | |
| dc.subject.other | Non-destructive test methods | |
| dc.subject.other | Ordinary Portland cement | |
| dc.subject.other | Replacement ratio | |
| dc.subject.other | Strength | |
| dc.subject.other | Void distributions | |
| dc.subject.other | X ray computerized tomography | |
| dc.subject.other | Computerized tomography | |
| dc.title | Monitoring macro voids in mortars by computerized tomography method | |
| dc.type | Article | |
| rdl.citation.openalex | 19 | |
| rdl.citation.scopus | 19 | |
| rdl.citation.wos | 17 | |
| rdl.oa.status | green | |
| rdl.oa.status | preprint | |
| rdl.scopus.quartile | Q1 | |
| rdl.sdg | SDG09 | |
| rdl.source.index | SCOPUS | |
| rdl.source.index | WOS | |
| rdl.wos.index | Science Citation Index Expanded (SCI-EXPANDED) |