Özet

This study explores the alternative polymer materials and selection process for joint implant liners, focusing on applying CES Selector software to identify suitable polymer materials. CES Selector provides an easy-to-use interface. It offers multiple selection methods, including boundary values and property constraints. Seven materials were excluded from the analysis, resulting in 19 potential candidates, including unconventional options like EVOH, PCTA, PESU, PI, PPA, PPC, PPSU, and PSU. The materials underwent evaluation based on key criteria, including tensile strength, Young’s modulus, compressive strength, fatigue strength, and fracture toughness. Overall, TPU exhibited a remarkable combination of high mechanical strength and adaptable Young’s modulus, making it a top contender. However, in other evaluation criteria, PI surpassed TPU, solidifying its potential as a superior choice. This systematic approach provides valuable insights for engineers and designers seeking innovative materials for joint implant liners. The study results broaden the range of materials used in implant manufacturing, providing potential alternatives that offer better long-term durability and performance.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/11896Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1088/2631-8695/ad7934Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
0
WoS
0
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorYilmaz, Galip
dc.contributor.authorGerdan, Zeynep
dc.contributor.authorÇolak, Murat
dc.date.accessioned2026-10-29T19:08:56.009502120Z
dc.date.available2026-10-29T19:08:56.009502120Z
dc.date.issued2024
dc.description.abstractThis study explores the alternative polymer materials and selection process for joint implant liners, focusing on applying CES Selector software to identify suitable polymer materials. CES Selector provides an easy-to-use interface. It offers multiple selection methods, including boundary values and property constraints. Seven materials were excluded from the analysis, resulting in 19 potential candidates, including unconventional options like EVOH, PCTA, PESU, PI, PPA, PPC, PPSU, and PSU. The materials underwent evaluation based on key criteria, including tensile strength, Young’s modulus, compressive strength, fatigue strength, and fracture toughness. Overall, TPU exhibited a remarkable combination of high mechanical strength and adaptable Young’s modulus, making it a top contender. However, in other evaluation criteria, PI surpassed TPU, solidifying its potential as a superior choice. This systematic approach provides valuable insights for engineers and designers seeking innovative materials for joint implant liners. The study results broaden the range of materials used in implant manufacturing, providing potential alternatives that offer better long-term durability and performance.
dc.identifier.articlenumber045539
dc.identifier.doi10.1088/2631-8695/ad7934
dc.identifier.issn2631-8695
dc.identifier.issue4
dc.identifier.scopus2-s2.0-85209140292
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/11896
dc.identifier.volume6
dc.identifier.wosWOS:001349962900001
dc.language.isoen
dc.publisherInstitute of Physics
dc.relation.ispartofEngineering Research Express
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCES selector software
dc.subjectjoint implant liners
dc.subjectmaterial selection
dc.subjectmechanical properties
dc.subjectpolymer materials
dc.subject.classificationEngineering, Multidisciplinary
dc.subject.classificationEngineering
dc.subject.otherCompressive strength
dc.subject.otherElastomers
dc.subject.otherError correction
dc.subject.otherHydroelasticity
dc.subject.otherPolymeric implants
dc.subject.otherTensile strength
dc.subject.otherBoundary values
dc.subject.otherCES selector software
dc.subject.otherJoint implant liner
dc.subject.otherJoint implants
dc.subject.otherMaterials selection
dc.subject.otherMechanical
dc.subject.otherMultiple selection
dc.subject.otherPolymer materials
dc.subject.otherProperty
dc.subject.otherSelection methods
dc.subject.otherFracture toughness
dc.titleExploring alternative polymer materials for joint liners: a software-guided material selection
dc.typeArticle
rdl.citation.scopus0
rdl.citation.wos0
rdl.oa.statusclosed
rdl.oa.statusgreen
rdl.oa.urlhttps://hdl.handle.net/20.500.12662/4681
rdl.scopus.quartileQ2
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexEmerging Sources Citation Index (ESCI)