Effect of using hybrid nanofluids as a coolant on the thermal performance of portable thermoelectric refrigerators

MakaleYalnız künyeScopus SJRQ1

Özet

This study investigated the effect of using hybrid nanofluids as a refrigerant in portable thermoelectric refrigerator applications on thermal performance. For this purpose, a cooling cabinet with an internal volume of 36 L was designed and produced. Then, the Peltier assembly, with a water-cooled block attached to its hot surface, was placed in this cooling cabinet from the middle of its front cover. With the help of a refrigerant, the heat was removed from the Peltier's hot surface and transferred to the atmosphere via a water-to-air heat exchanger. Hybrid nanofluids prepared with Al2O3-TiO2-SiO2 and nanoparticles and water were used as the refrigerant in the system. To evaluate the thermal performances of these hybrid nanofluids, the tests were repeated using water without added nanoparticles as the reference case. According to the results obtained from the experimental study, it was observed that in all cases, tests using nanofluids gave better results than the reference cases. In addition, it was determined that the efficiency obtained from the system increased as the nanoparticle ratio in the mixture increased in all cases. Despite significant improvements in cooling cabinet and cooled product temperatures in hybrid nanofluids, the COP values ​​of the systems are slightly lower than in the reference case due to the Peltier effect. Considering the difference between the first and last temperatures of the cooled cabinet, the greatest improvement compared to the reference situation was determined as 30.3 % in the case of loaded state conditions and in the case of using 2 % Al2O3-TiO2-SiO2-Water nanofluid. For the unloaded conditions, this value was obtained as 25.1 % in the case of using 2 % Al2O3-TiO2-SiO2-Water nanofluid. On the other hand, for the unloaded condition, the lowest COP value was calculated as 0.47 and 0.45 when Al2O3-TiO2-SiO2-Water nanofluid was used in 1 % and 2 % mass fraction, respectively. For the loaded condition, this value was found as 0.48 in the case where 1 % Al2O3-TiO2-SiO2-Water and 0.47 in the case where 2 % Al2O3-TiO2-SiO2-Water nanofluid was used.

Anahtar Kelimeler

RDL Kalıcı Bağlantı (PID)
https://rdlopen.rawdatalibrary.net/r/bayburt/11611Resmi atıflarda kullanılan kalıcı adres
DOI
https://doi.org/10.1016/j.seta.2022.102685Yayıncı resmi DOI adresi
İndeks kayıtları
Kaydın indeks veri tabanlarındaki sayfası (aktarımda alınan kayıt numarasıyla). Erişim, indeksin kendi koşullarına bağlıdır.
Atıflar
Scopus
27
WoS
21
Her kaynağın kendi saydığı toplam atıf; aktarım ve zenginleştirme sırasında alındı.
Tam Kayıt
AlanDeğerDil
dc.contributor.authorMert Cuce, Pinar
dc.contributor.authorCuce, Erdem
dc.contributor.authorGuclu, Tamer
dc.contributor.authorShaik, Saboor
dc.contributor.authorAlshahrani, Saad
dc.contributor.authorAhamed Saleel, C.
dc.date.accessioned2026-10-29T19:08:35.741696398Z
dc.date.available2026-10-29T19:08:35.741696398Z
dc.date.issued2022
dc.description.abstractThis study investigated the effect of using hybrid nanofluids as a refrigerant in portable thermoelectric refrigerator applications on thermal performance. For this purpose, a cooling cabinet with an internal volume of 36 L was designed and produced. Then, the Peltier assembly, with a water-cooled block attached to its hot surface, was placed in this cooling cabinet from the middle of its front cover. With the help of a refrigerant, the heat was removed from the Peltier's hot surface and transferred to the atmosphere via a water-to-air heat exchanger. Hybrid nanofluids prepared with Al2O3-TiO2-SiO2 and nanoparticles and water were used as the refrigerant in the system. To evaluate the thermal performances of these hybrid nanofluids, the tests were repeated using water without added nanoparticles as the reference case. According to the results obtained from the experimental study, it was observed that in all cases, tests using nanofluids gave better results than the reference cases. In addition, it was determined that the efficiency obtained from the system increased as the nanoparticle ratio in the mixture increased in all cases. Despite significant improvements in cooling cabinet and cooled product temperatures in hybrid nanofluids, the COP values ​​of the systems are slightly lower than in the reference case due to the Peltier effect. Considering the difference between the first and last temperatures of the cooled cabinet, the greatest improvement compared to the reference situation was determined as 30.3 % in the case of loaded state conditions and in the case of using 2 % Al2O3-TiO2-SiO2-Water nanofluid. For the unloaded conditions, this value was obtained as 25.1 % in the case of using 2 % Al2O3-TiO2-SiO2-Water nanofluid. On the other hand, for the unloaded condition, the lowest COP value was calculated as 0.47 and 0.45 when Al2O3-TiO2-SiO2-Water nanofluid was used in 1 % and 2 % mass fraction, respectively. For the loaded condition, this value was found as 0.48 in the case where 1 % Al2O3-TiO2-SiO2-Water and 0.47 in the case where 2 % Al2O3-TiO2-SiO2-Water nanofluid was used.
dc.description.sponsorshipDeanship of Scientific Research, King Faisal University, DSR, KFU, (RGP 2/32/43)
dc.identifier.articlenumber102685
dc.identifier.doi10.1016/j.seta.2022.102685
dc.identifier.eissn2213-1396
dc.identifier.issn2213-1388
dc.identifier.scopus2-s2.0-85137061882
dc.identifier.urihttps://rdlopen.rawdatalibrary.net/r/bayburt/11611
dc.identifier.volume53
dc.identifier.wosWOS:000892101400010
dc.language.isoen
dc.publisherElsevier Ltd
dc.relation.ispartofSustainable Energy Technologies and Assessments
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectCoefficient of Performance
dc.subjectCooling Power
dc.subjectHybrid Nanofluids
dc.subjectNanofluid coolants
dc.subjectThermoelectric refrigeration
dc.subject.classificationGreen & Sustainable Science & Technology
dc.subject.classificationEnergy & Fuels
dc.subject.classificationScience & Technology - Other Topics
dc.subject.otherAlumina
dc.subject.otherAluminum oxide
dc.subject.otherEfficiency
dc.subject.otherElectronic cooling
dc.subject.otherNanofluidics
dc.subject.otherRefrigerants
dc.subject.otherRefrigerators
dc.subject.otherSilica
dc.subject.otherSilicon
dc.subject.otherSiO2 nanoparticles
dc.subject.otherTiO2 nanoparticles
dc.subject.otherCoefficient of Performance
dc.subject.otherCondition
dc.subject.otherCooling power
dc.subject.otherHybrid nanofluid
dc.subject.otherNanofluid coolant
dc.subject.otherNanofluids
dc.subject.otherPeltier
dc.subject.otherThermal Performance
dc.subject.otherThermoelectric refrigerators
dc.subject.otherWater nanofluids
dc.subject.othercooling
dc.subject.otherefficiency measurement
dc.subject.otherexperimental study
dc.subject.otherhybrid
dc.subject.othernanoparticle
dc.subject.otherperformance assessment
dc.subject.otherwater flow
dc.subject.otherTitanium dioxide
dc.titleEffect of using hybrid nanofluids as a coolant on the thermal performance of portable thermoelectric refrigerators
dc.typeArticle
rdl.citation.scopus27
rdl.citation.wos21
rdl.oa.statusclosed
rdl.scopus.quartileQ1
rdl.source.indexSCOPUS
rdl.source.indexWOS
rdl.wos.indexScience Citation Index Expanded (SCI-EXPANDED)